Rudenberg’s Formula for the Placement of an Anode Ground Bed Introduction This formula considers the attenuation of the pipe to determines the required structure voltage based on the current output....
API 520 – Relief Valves Requiring Capacity Certification Introduction The ASME Code requires that capacity certification be obtained for PRVs designed for liquid service. The procedure for obtaining...
API 520 – Relief Valves Requiring No Capacity Certification Introduction This method assumes an effective coefficient of discharge, Kd = 0.62, and 25 % overpressure. An additional capacity correction...
Relief Valve: Reactive Force Introduction Where: ๐นโ โ Force due to Change in Momentum (lbs) ๐น๐ฃ โ Force due to Discharge (lbs) ๐น๐ก =...
Reinforcement of Welded Branch Connection Introduction One of the first methods of providing branch connections was to stub a branch line into a run. Sometimes...