Angled Line Explosive Charge
An angled-line source that is simplified into an equivalent parallel line source if the its standoff distance is equal to or less than the effective length of the line. The calculation uses a point source solution that simplifies methods for an angled line source.
Minimum distance from the pipeline to the nearest explosive charge must be greater than two times outside pipe diameter.

Maximum allowable angle between pipe and explosive line must be less than 90Λ

π ,π΄Β β Distance from the Charge to the Pipeline(ft)
π΅Β β Angle Between Pipe and Grid(deg), convert to Radians =Β π΅(0.0175)
πΒ β MAOPβMaximum Allowable Operating Pressure(psi)
π·Β β Pipeline Outside Diameter(in)
π‘Β β Pipe Wall Thickness(in)
πβΒ β Hoop Stress(psi)

πΏΒ β Total Length of Explosive Line(ft)
πΏ1Β β Spacing Length Between Charges in Explosive Line(ft)
πΒ β Total Charge Weight(lbs)
π1Β β Weight of Single Charge(lbs)
π1Β β Number of Charges in Explosive Line

ππΒ β Maximum Circumferential =Β ππΒ β Maximum Longitudinal Stress(psi)
πΒ β Equivalent Energy Release Ratio
πΒ β Weight of Single Charge(lbs)
πΈΒ β Modulus of Elasticity
π‘Β β Pipe Wall Thickness(in)
ππ‘Β β Combined Hoop and Circumferential Stress(psi)

Blasting Conditions for combined Stress Level
πΆππππππ >%ππππ β NOT ACCEPTABLE/πΆππππππ <%ππππ β ACCEPTABLE
Input Parameters
- To create a new case, click the βAdd Caseβ button
- Select the Angled Line Explosive Charge application from the Pipe Blast module.
- Enter Case Name, Location, Date and any necessary notes.
- Fill out all required fields.
- Make sure the values you are inputting are in the correct units.
- Click the CALCULATE button.
- Pipe Outside Diameter
- Pipe Wall Thickness
- Specified Minimum Yield Strength
- Maximum Allowable Combined Stress Level – SMYS
- Manufacturer
- Explosive Type
- Equivalent energy release ratio
- MAOP – Maximum Allowable Operating Pressure
- N1 – Number of Charges in Explosive Line
- L1 – Spacing Length Between Charges in Explosive Line
- W1 – Weight of Single Charge
- n – Equivalent Energy Release Ratio
- A – Distance of the Nearest Charge to Pipeline
- B – Angle Between Pipe and Grid

Outputs/Reports
- View the results.
- If an input parameter needs to be edited be sure to hit the CALCULATE button after the change.
- To SAVE, fill out all required case details then click the SAVE button.
- To rename an existing file, click the SAVE As button. Provide all case info then click SAVE.
- To generate a REPORT, click the REPORT button.
- The user may export the Case/Report by clicking the Export to Excel/PowerPoint icon.
- To delete a case, click the DELETE icon near the top of the widget.
- Total Length of Explosive Line
- Total Charge Weight
- Sh – Hoop Stress
- Sc-Maximum Circumferential = Sl-Maximum Longitudinal Stress
- St – Combined Hoop && Circumferential Stress
- S – Total Combined Stress
- Calculated Percent of SMYS
- Blasting Conditions for Combined Stress Level:

Related Links
Pipeline HUB β User Resources
Table of Contents
Table of Pages
Table of Contents
- Pipeline HUB User Resources
- AC Mitigation PowerTool
- API Inspector's Toolbox
- Horizontal Directional Drilling PowerTool
- Crossings Workflow
- Hydrotest PowerTool
- Pipeline Toolbox
- Encroachment Manager
- PRCI AC Mitigation Toolbox
- PRCI RSTRENG
- RSTRENG+
- Ad-hoc Analysis
- Database Import
- Data Availability Dashboard
- ESRI Map
- Report Builder
- Crossings Workflow
- Hydrotest PowerTool
- Investigative Dig PowerTool
- Hydraulics PowerTool
- External Corrosion Direct Assessment Procedure - RSTRENG
- Canvas
- Definitions
- Pipe Schedule and Specifications Tables