AGA 3 - Volume Flow Rate Calculation - Method I

Orifice Flow Equation

The accepted one-dimensional equation for mass flow through a concentric, square edged orifice meter is stated in the Equations below. The derivation is based on conservation of mass and energy, one-dimensional fluid dynamics, and empirical functions such as equations of state and thermodynamic process statements. Any derivation is accurate when all the assumptions used to develop it are valid. As a result, an empirical orifice plate coefficient of discharge is applied to the theoretical equation to adjust for multidimensional viscous fluid dynamic effects. In addition, an empirical expansion factor is applied to the theoretical equation to adjust for the reduction in fluid density that a compressible fluid experiences when it passes through an orifice plate.

The fundamental orifice meter mass flow equation is as follows:
PTLB Regulators 2.2 Orifice.png
Where:
π‘žπ‘š βˆ’ Mass Flow Rate
𝐢𝑑 βˆ’ Orifice Plate Coefficient of Discharge
𝑑 βˆ’ Orifice Plate Bore Diameter [in]
𝐸𝑣 βˆ’ Velocity Approach Factor
βˆ†π‘ƒ βˆ’ Orifice Differential Pressure ,in ,𝐻-2.0.at 60℉
πœ‹ βˆ’ Universal Constant=3.14159
π‘Œ βˆ’ Expansion Factor
𝑔𝑐 βˆ’ Dimensional Conversion Factor
πœŒπ‘‘,π‘Β βˆ’ Density of the Fluid at Flowing Conditions (𝑃𝑓,𝑇𝑓)

The orifice meter is a mass meter from which a differential pressure signal is developed as a function of the velocity of the fluid as it passes through the orifice plate bore. Manipulation of the density variable in the equation permits calculation of flow rate in either mass or volume units. The volumetric flow rate at flowing (actual) conditions can be calculated using the following equation:

d=d
The volumetric flow rate at base (standard) conditions can be calculated using the following equation:
d=d
The mass flow rate (π‘žπ‘š) can be converted to a volumetric flow rate at base (standard) conditions (𝑄𝑣) if the fluid density at the base conditions (πœŒπ‘) can be determined or is specified.

Orifice Plate Bore Diameter
The orifice plate bore diameter, d. is defined as the diameter at flowing conditions and can be calculated using the following equation:
d=d
𝑑 βˆ’ Orifice Plate Bore Diameter [in]
π‘‘π‘Ÿ βˆ’ Mean Orifice Bore Diameter [in]
𝛼1Β βˆ’ Linear Coefficient of Thermal Expansion of Orifice Plate Material [in/inβˆ™β„‰]
π‘‘π‘“Β βˆ’ Flowing Gas Temperature [℉]
π‘‡π‘ŸΒ βˆ’ Reference Temperature Prifice Plates/Tubes [℉]

The meter tube internal diameter, D, is defined as the diameter at flowing conditions and can be calculated using the following equation:
D=D
𝐷 βˆ’ Meter Tube Internal Diameter [in]
π·π‘ŸΒ βˆ’ Mean Meter Tube Diameter [in]
𝛼2Β βˆ’ Linear Coefficient of Thermal Expansion of Meter Tube [in/inβˆ™β„‰]
π‘‘π‘“Β βˆ’ Flowing Gas Temperature [℉]
π‘‡π‘ŸΒ βˆ’ Reference Temperature Prifice Plates/Tubes [℉]
PTLB Regulators 2.1 Linear.png
Note: For flowing temperature conditions outside those stated above and for other materials, refer to the American Society for Metals Handbook. ᡃFor flowing conditions between -100Β°F and +300Β°F, refer to ASME PTC 19.5. ᡇFor flowing conditions between -7Β°F and + 154Β°F, refer to API Manual of Petroleum Measurement Standards, Chapter 12, Section 2.

Empirical Coefficient of Discharge Equation for Flange-Tapped Orifice Meters
The concentric, square-edged, flange-tapped orifice meter coefficient of discharge, ,𝐢-𝑑.(FT), equation, developed by Reader-Harris/Gallagher (RG), is structured into distinct linkage terms and is considered to best represent the current regression data base. The equation is applicable to nominal pipe sizes of 2 inches (50 millimeters) and larger; diameter ratios (𝛽) of 0.1-0.75, provided the orifice plate bore diameter, d” is greater than 0045 inch (11.4 millimeters); and pipe Reynolds numbers (,𝑅𝑒-𝐷.) greater than or equal to 4000.

PTLB Regulators 2.1 Empirical.png

Where:
𝛽 βˆ’ Diameter Ratio= ,𝑑-𝐷.
𝐢𝑑(𝐹𝑇) βˆ’ Coefficientof Discharge at a Specific Reynolds number for Flangeβˆ’Tapped Orifice Meter
𝐢𝑖(𝐹𝑇) βˆ’ Coefficientof Discharge at infinite Reynolds number for Flangeβˆ’Tapped Orifice Meter
𝐢𝑖(𝐢𝑇) βˆ’ Coefficientof Discharge infinite Reynolds number for Cornerβˆ’Tapped Orifice Meter
𝐿1Β βˆ’ dimentionless correction for the tap location 𝑒 βˆ’ Napoerian Constant=2.71828
𝑁4Β = 1.0 when D is in Inches=25.4 when D is in millimeters π‘…π‘’π·Β βˆ’ pipe Reynolds number

Reynold’s Number
The RG equation uses pipe Reynolds number as the correlating parameter to represent the change in the orifice plate coefficient of discharge, Cd, with reference to the fluid’s mass flow rate (its velocity through the orifice), the fluid density, and the fluid viscosity. The pipe Reynolds number can be calculated using the following equation:

𝐷 βˆ’ Meter Tube Internal Diameter [in]
πœ‹ βˆ’ Universal Constant=3.14159
π‘žπ‘šΒ βˆ’ Mass Flow Rate
π‘…π‘’π·Β βˆ’ pipe Reynolds number
πœ‡ βˆ’ Absolute Viscosity of Fluid

Velocity of Approach Factor
The velocity of approach factor, 𝐸𝑣, is calculated as follows:
PTLB Regulators Velocity Approach.png Where:
𝛽 βˆ’ Diameter Ratio
πΈπ‘£Β βˆ’ Velocity Approach Factor
𝑑 βˆ’ Orifice Plate Bore Diameter ,in.
𝐷 βˆ’ Meter Tube Internal Diameter [in]

This assumption defines the expansion as reversible and adiabatic (no heat gain or loss). Within practical operating ranges of differential pressure, flowing pressure, and temperature, the expansion factor equation is insensitive to the value of the isentropic exponent. As a result, the assumption of a perfect or ideal isentropic exponent is reasonable for field applications.

The application of the expansion factor is valid if the following dimensionless pressure ratio criteria are followed:
PTLB Regulators Velocity Approach 2.png
Where:
𝑁3Β βˆ’ Unit Conversion Factor
𝑃𝑓1Β βˆ’ Absolute Static Pressure at Upstream Tap [psi]

𝑃𝑓2Β βˆ’ Absolute Static Pressure at Downstream Tap [psi]
βˆ†π‘ƒ βˆ’ Orifice Differential Pressure [in 𝐻20] at 60℉
Upstream/Downstream Expansion Factor
The upstream expansion factor requires determination of the upstream static pressure, the diameter ratio, and the isentropic exponent. If the absolute static pressure is taken at the upstream differential pressure tap, then the value of the expansion factor, π‘Œ1Β , shall be calculated as follows:
PTLB Regulators Upstream.png
When the upstream static pressure is measured,
PTLB Regulators Upstream 2.png
When the downstream static pressure is measured,
PTLB Regulators Upstream 3.png
π‘Œ1Β βˆ’ Upstream Expansion Factor
𝑁3Β βˆ’ Unit Conversion Factor
π‘₯1Β βˆ’ Ratio of Differential Pressure to Asolute Static Pressure
𝑃𝑓1Β βˆ’ Absolute Static Pressure at Upstream Tap [psi]
𝑃𝑓2Β βˆ’ Absolute Static Pressure at Downstream Tap [psi]
βˆ†π‘ƒ βˆ’ Orifice Differential Pressure ,in ,𝐻-2.0.at 60℉
π‘˜ βˆ’ Isentropic Exponent
𝛽 βˆ’ Diameter Ratio

The downstream expansion factor requires determination of the downstream static pressure, the upstream static pressure, the downstream compressibility factor, the upstream compressibility factor, the diameter ratio, and the isentropic exponent. The value of the downstream expansion factor, π‘Œ2, shall be calculated using the following equation:

PTLB Regulators Upstream 4.png When the upstream static pressure is measured,
PTLB Regulators Upstream 5.png

When the downstream static pressure is measured,
PTLB Regulators Upstream 6.png
π‘Œ1Β βˆ’ Upstream Expansion Factor π‘Œ2Β βˆ’ Downstream Expansion Factor 𝑁3Β βˆ’ Unit Conversion Factor π‘₯1Β βˆ’ Ratio of Differential Pressure to Asolute Static Pressure π‘₯1/π‘˜ βˆ’ Upstream Acoustic Ratio 𝑃𝑓1Β βˆ’ Absolute Static Pressure at Upstream Tap [psi] 𝑃𝑓2Β βˆ’ Absolute Static Pressure at Downstream Tap [psi] 𝑍𝑓1Β βˆ’ Fluid Compressibility at Upstream Tap [psi] 𝑍𝑓2Β βˆ’ Fluid Compressibility at Downstream Tap [psi] βˆ†π‘ƒ βˆ’ Orifice Differential Pressure ,in ,𝐻-2.0.at 60℉ π‘˜ βˆ’ Isentropic Exponent

Input Parameters

  1. To create a new case, click the β€œAdd Case” button
  2. Select the AGA 3 – Volume Flow Rate Calculation – Method I application from the Regulators & Meters module list.
  3. Enter Case Name, Location, Date and any necessary notes.
  4. Fill out all required fields.
  5. Make sure the values you are inputting are in the correct units.
  6. Click the CALCULATE button.

  • Molecular Weight
  • Static Pressure Measurements are Taken from the
  • Linear Coefficient of Thermal Expansion
    • Orifice
    • Meter Tube
  • Reference Temperature Orifice Plates/Tube
  • Compressibility Factor at Flowing Conditions
  • Compressibility Factor at Base Conditions
  • Compressibility Factor at Standard Conditions
  • Mean Orifice Bore Diameter
  • Mean Meter Tube Internal Diameter
  • Real Gas Relative Density
  • Differential Pressure [in.H2O] at 60 deg F
  • Base Pressure
  • Static Pressure
  • Contract Base Temperature
  • Flowing Gas Temperature
  • Carbon Dioxide
  • Nitrogen
  • Gas Dynamic Viscosity
  • Isentropic Exponent
PLTB Reg Gas_2.2 Input Rev_090320.png PLTB Reg Gas_2.2 Input_2 Rev_090320.png

Outputs/Reports

  1. View the results.
  2. If an input parameter needs to be edited be sure to hit the CALCULATE button after the change.
  3. To SAVE, fill out all required case details then click the SAVE button.
  4. To rename an existing file, click the SAVE As button. Provide all case info then click SAVE.
  5. To generate a REPORT, click the REPORT button.
  6. The user may export the Case/Report by clicking the Export to Excel/PowerPoint icon.
  7. To delete a case, click the DELETE icon near the top of the widget.

  • Orifice Diameter
  • Tube Diameter
  • Diameter Ratio
  • Velocity Approach Factor
  • Expansion Factor
  • Reynolds Number
  • Coefficient of Discharge
  • Flow Rate at Standard Conditions
  • Flow Rate at Base Conditions