  3. How is Required Area calculated for Branched Weld Connection?

How is Required Area calculated for Branched Weld Connection?

The calculation is using the following is the equation that we use for A3 – REQUIRED AREA

A3 = Ar – A1-A’2

where,

  • Ar = Reinforcement Required
  • A1= Reinforcement Provided
  • A’2 = Corrected Effective Area

Note: If HUBPL calculates A3 < 0, it will be set to 0.
Calculations for the variables above is documented in the TTI Support Wiki at:Reinforcement of Welded Branch Connection

E.g. Demo case in Reinforcement of Welded Branch Connection – ASME B31.8 (Revision: 10.0.0) (Gas)

E.g. Demo case (A3 > 0):

From the demo case, the following is calculated:

Ar = 2.423 inch2

A1 = 0.530 inch2

A’2 = 0.392 inch2

A3= 2.423-0.530-0.392 inch2 = 1.501 inch2

E.g. Case where A3 = 0:

Ar = 0.199 inch2

A1 = 0.676 inch2

A’2 = 0.216 inch2

A3= Ar – A1-A’2 = -0.693 inch2

Because A3 was calculated, to be < 0 from the data provided to calculate the variables above, HUBPL will calculate A3’s final value to 0.